How to Read Pumice Block Thermal Conductivity

Read the two thermal conditions in the Gayret SW approvals. Distinguish product conductivity values from whole-building performance.

AT A GLANCE

Gayret SW does not have one unconditional thermal-conductivity value. Each approval reports equivalent conductivity under two separate assessment conditions.

Values for 19 SW and 25 SW

Table 1 reports 0.103 W/mK for 19 SW and 0.105 W/mK for 25 SW under the condition labelled “900 kg/m³ – 3 mm sıva” in the Turkish source. Under “1800 kg/m³ – 7 mm sıva”, the respective values are 0.131 and 0.133 W/mK.

Keep the condition with the value

These are the source document’s condition labels. Page 3 also describes mortar-built walls, conditioning and measurement. A condition label is not, by itself, an installation specification.

Does this establish energy-bill savings?

The supplied documents do not specify a fixed percentage reduction in energy bills or a universal decision about additional external insulation. Do not present a product conductivity figure as a whole-building outcome.

Comparing alternatives

Check wall thickness, the reported property and the assessment conditions together. Comparing figures from different conditions does not create a like-for-like comparative test.

Sources (Turkish PDFs): 19 SW UTO · p. 3–4 · 25 SW UTO · p. 3–4